Property | Type | Description |
Billing Period End Date |
Date/Time Numeric |
If the type of EOB is defined as DEFINE_DAY_OF_MONTH, then this property holds the defined day. |
Billing Period Starts |
Numeric |
This is the number of Starts for the current billing period. |
Billing Period Time: Min/Max |
Date/Time Numeric |
Displays the date and time that the minimum or maximum occurred during the current billing period. Applicable to Minimum or Maximum calculation type only. |
Billing Period Type |
Multi-State |
This is an enumerated value determining what type of End-of-Billing period to use. |
Billing Period Value |
Numeric |
This is the calculated value for the current billing period. |
Calculation Constant |
Numeric |
This edited parameter is the Base Temperature for Degree Day calculations or it is the Conversion Factor for Cool Flow Rate and Heat Flow Rate calculations. |
Calculation Type |
Multi-State |
This property is the type of calculation that is to be done. This enumerated type has the following options: Average, Cool Flow Rate, Heat Flow Rate, Maximum, Meter Totalization, Minimum, Peak for 15 Minute Interval, Peak for 30 Minute Interval, Peak for 5 Minute Interval, Peak for 60 Minute Interval, Total Cooling Degree Days, Total Heating Degree Days, Total Run Hours/Starts. |
Current Value: Ref |
Numeric |
Displays the current value of the calculation referencer |
Enable Delay Countdown |
Numeric |
If the Enable On Delay property has been edited (given a value other than zero), this property is a countdown counter showing the time left before the calculation is enabled. |
Enable Last State |
Binary |
This stores the value of the enable referencer the last time it was evaluated for use. If the enable referencer can not be evaluated this value is used. |
Enable On Delay |
Numeric |
For some items (such as a entering or leaving water temp) it takes a few minutes until the value comes into a valid range. The ON delay will wait an edited amount of time after the Enable Point transitions from OFF to ON before accumulating the value. |
Enable Status |
Binary |
This is the value to which enable referencer is evaluated. |
Enable: Ref |
Referencer/ Binary |
If this point is undefined, accumulations will happen continuously. If this point is defined and ON, the accumulation will take place; otherwise, if this point is defined and OFF, the accumulation will not take place. If the enable referencer fails to evaluate, the Enable Last State property value is used. |
End of Billing Selection |
Binary |
This is a boolean value to select if End of Billing period logic is to be used. |
Last Billing Period Starts |
Numeric |
This is the number of Starts for the last billing period. |
Last Billing Period Time: Min/Max |
Date/Time Numeric |
Displays the date and time that the minimum or maximum occurred during the last billing period. Applicable to Minimum or Maximum calculation type only. |
Last Billing Period Value |
Numeric |
This is the calculated value for the last billing period. |
Object Identifier |
Object ID |
This is the object identifier property. It is the unique identifier for a given instance of a calculation object. It is only unique within the context of a given BCU. |
Object Name |
Character |
This is the object name property. In calculation objects this will contain the name of the calculation object. It is a text string. |
Object Type |
Multi-State |
This is the object type property. It is an enumeration that identifies a calculation object. |
Property Reference |
Numeric |
This is the value of the property reference which is being used in the calculation. This also displays the referenced object and property whose value is used in all calculations. |
Security Class |
Numeric |
This is the security class property. It is a word that is defined on a bitwise basis. Each bit defines a particular security class and is used to control operator access to each calculation object instance. This is only used by the Workstation, all BCU applications ignore it. |
Temp 1: Ref |
Numeric |
This is the value of the analog input used as the temperature 1 (leaving) in heating or cooling flow rate calculations |
Temp 2: Ref |
Numeric |
This is the value of analog input used as the temperature 2 (entering) in heating or cooling Flow rate calculations. |
Todays Starts |
Numeric |
This is the number of Starts today. |
Todays Time: Min/Max |
Numeric |
Displays the date and time that the minimum or maximum occurred during for the previous day. Applicable to Minimum or Maximum calculation type only |
Todays Value |
Numeric |
This is today’s current calculated value. |
Units |
Multi-State |
Enumerated value to designate the units of the calculation. |
Update Tag |
Numeric |
This is the upload/download tag property. Its purpose is to keep the Workstation and BCU copies of the object instance in synchronization. |
Yesterdays Starts |
Numeric |
This is the number of Starts yesterday. |
Yesterdays Time: Min/Max |
Numeric |
Displays the date and time that the minimum or maximum occurred during for the previous day. Applicable to Minimum or Maximum calculation type only. |
Yesterdays Value |
Numeric |
This is yesterday’s calculated value. |